revised mass balance check to be function of convergence criteria added output (6) for mass balance error flag. Mid-timestep inversion mixing was removed as well. In prior versions of this model, auxiliary could change midway through a timestep. Bugfix: Type154 underwent a major rewrite starting over from generic tank model, implementing auxiliary controls with one decision per timestep (ON or OFF).Bugfix: Type153 underwent a major rewrite starting over from generic tank model, implementing auxiliary controls with one decision per timestep (ON or OFF).corrected equation for calculating heat transfer to the ambient added output (6) for mass balance error flag corrected error message text on FoundBadInput errors. Bugfix: Type38 – the auxiliary heat would never turn on.Bugfix: 301 (complex fenestration model) – wrong area was used (module area of window type instead of surface area).Bugfix: TrnsysFunctions.f90 – deleted blank lines in the ShowMessage() function.Bugfix: Type69.f90 – deleted unused variables in source code.Enhancement: Revisions to the trnViewBUI installer.Enhancement: Revisions to A4_trnViewBUI.pdf.Block of Type numbers newly reserved for French community TRNSYS components. Enhancement: Revisions to the 07-ProgrammersGuide manual.
TRNSYS EXAMPLES CODE
Documentation corresponds to code modifications made in v. Enhancement: Revisions to the Type153 and 154 sections of the 04-MathematicalReference manual.Enhancement: Revisions to the 02-SimulationStudio manual.Bugfix: Type39 (variable volume tank): Starting the tank fully empty resulted in a floating point error.Bugfix: Type84 (moving average): a variable had been created toĪllow for easy recompilation with more timesteps in the moving average.The convergence routine won’t allow the voltage to go below its minimum The power being demanded is too big (the voltage can go negative). Bugfix: Type47 (battery): the code tried to converge on a voltageĪnd then checked to see if the converged voltage was below the allowable.Bugfix: The flow rates in the SDHW project template were corrected to match those in the SDHW example.Bugfix: The TRNSYS.h file (for C++ components) was updated to include a header for the TYPECK subroutine.Bugfix: The PV-Inverter example referenced an incorrect data file and generated an error.Bugfix: The units of some parameters and inputs to Type167 (gasĬompressor) were incorrect and needed to be added to the unit.(compressed gas storage) were incorrect and needed to be added to the Bugfix: The units of some parameters and inputs to Type164.
TRNSYS EXAMPLES MANUAL
MathematicalReference manual were incorrect and were fixed to match the Bugfix: The coefficients in equation 4.8.9-3 of the.
TRNSYS EXAMPLES UPDATE
TRNSYS EXAMPLES WINDOWS
Bugfix: Output 140 runtime error for completely unshaded windows due to a wrong pointer.Bugfix: Balance 907 (moisture) set very small values to 0.d0 (error with E-format e.g.Bugfix: Generate Radiance files: an error might occur for “classic” or “dds” mode while generating dc files.TRNBuild – User interface of the multizone building model Enhancement: Revisions to the trnViewBUI installer.Enhancement: Revisions to 05-MultizoneBuidling.pdf.